Refurbished Panoramic PC-4000 Digital Panoramic X-Ray System

Price per unit. No shipping charged at checkout — freight is quoted and confirmed with you before it ships.
Product details & specifications
Panoramic PC-4000 Digital Panoramic X-Ray System
The Panoramic PC-4000 is a premium digital panoramic imaging system using direct digital CdTe sensor technology to deliver sharp, high-contrast diagnostic images with TMJ imaging, extraoral bitewing capability, EV Clarity image enhancement, and autofocus image correction. It features intuitive touchpad controls, automatic patient positioning assistance, and high-resolution digital image acquisition in approximately 12 seconds. Professionally refurbished by ABC Dentalworks, this unit was inspected across the X-ray generator, digital sensor, rotating gantry, positioning system, exposure controls, software, safety systems, and electronics before shipment.
| Manufacturer | Panoramic Corporation |
| Model | PC-4000 |
| Equipment Type | Digital Panoramic X-Ray System |
| Sensor Technology | Direct Digital CdTe Sensor |
| Image Resolution | 3200 × 1500 dpi |
| Exposure Time | Approximately 12 Seconds |
| Tube Voltage | 70–90 kVp |
| Tube Current | 6 mA |
| Condition | Professionally Refurbished, Inspected & Tested |
| Installation | Professional installation and calibration recommended following delivery |
Included Components & Accessories
- Panoramic PC-4000 X-Ray Unit
- Digital Sensor
- Computer (If Shown)
- Acquisition Software (As Shown)
- Patient Positioning Components
- Installation Hardware (As Shown)
Condition
This unit underwent a comprehensive inspection before shipment, including generator testing, sensor evaluation, calibration, software verification, motion testing, cleaning, and final imaging quality verification. Equipment configuration is based on the actual unit shown; please review all product photographs carefully to verify included accessories, software, and cosmetic condition.
Replacement X-Ray Tube
The column data plate shows a May 2014 date of manufacture, while the X-ray tube housing label shows a June 2019 manufacture date — both carrying serial number 20880. This indicates the tube was replaced approximately five years into the unit's service life. Both plates are photographed in the listing gallery.
Registered to Service Radiation Equipment
ABC Dentalworks is a state-registered radiation-machine servicer, registered with the Florida Department of Health, Bureau of Radiation Control, to install, service, repair and calibrate radiation machines — Certificate of Registration V-1170. X-ray equipment purchased from us is inspected and tested by a state-registered facility. We ship nationwide and can advise on installation and compliance requirements in your state. Certificate available on request.
Before You Purchase
Please review all listing photographs carefully to verify the exact equipment configuration. Contact ABC Dentalworks at 727-388-4223 or sales@abcdentalworks.com with any questions regarding compatibility, installation, shipping, or financing before purchasing.